f6 tolerance (shaft): ISO 286 chart up to 500 mm

f6 is an ISO tolerance class for shafts (external features) under ISO 286. At Ø25 mm it means −20 / −33 µm: the size may lie between 24.967 and 24.980 mm. Below are the deviations for every nominal size up to 500 mm and the fits that use f6.

Updated 2026-10-30 · Basis: ISO 286-1:2010 and ISO 286-2:2010 · irot Erstmuster

f6 chart: deviations for all nominal sizes up to 500 mm

Deviations in µm (1 µm = 0.001 mm). A nominal size belongs to the row »over … up to and including …«: exactly 30 mm is in the row ending at 30, 30.1 mm in the next one.

Nominal size over – to (mm)Upper deviationLower deviationTolerance
0 – 3−6−126
3 – 6−10−188
6 – 10−13−229
10 – 18−16−2711
18 – 30−20−3313
30 – 50−25−4116
50 – 80−30−4919
80 – 120−36−5822
120 – 180−43−6825
180 – 250−50−7929
250 – 315−56−8832
315 – 400−62−9836
400 – 500−68−10840

f6 for your nominal size

mm

How f6 is built

An ISO tolerance class is a letter and a number. Capital letters stand for holes, small letters for shafts. The letter f sets the position of the tolerance zone; at Ø25 mm it lies entirely below the nominal size: the shaft is always smaller than nominal. The number 6 is the standard tolerance grade IT6: it sets how wide the zone is – 13 µm at Ø25 mm.

The tolerance grows with the nominal size: 6 µm in the smallest row (0 – 3 mm), 40 µm in the largest (400 – 500 mm). On a drawing the class follows the dimension, as in »Ø25 f6«; the inspection plan turns that into the limits 24.967 and 24.980 mm.

Fits with f6 at Ø25 mm

Hole-basis system: the hole is H, the shaft f6. Clearance in µm; a minus means interference. Sorted from the largest minimum clearance to the largest interference.

FitTypeMax. clearanceMin. clearance
H6/f6clearance fit4620
H7/f6clearance fit5420

Frequently asked questions about f6

What does f6 mean?

f6 is an ISO tolerance class for shafts (external features): the letter f sets the position of the tolerance zone, the number 6 the standard tolerance grade IT6. At Ø25 mm that gives −20 / −33 µm, i.e. 24.967 to 24.980 mm.

What are the f6 limits at Ø10 and Ø50 mm?

Ø10 f6: −13 / −22 µm (9.978 to 9.987 mm). Ø50 f6: −25 / −41 µm (49.959 to 49.975 mm).

Is f6 a clearance fit?

A tolerance class on its own is not a fit – only together with its mating part. H7/f6 at Ø25 mm is a clearance fit (maximum clearance 54 µm, minimum clearance 20 µm; a minus means interference).

More tolerance classes

Same letter f, other grades: f7

Shafts in grade 6: h6 · g6 · js6 · k6 · m6 · n6 · p6 · r6 · s6