Tolerance chart
r6 tolerance (shaft): ISO 286 chart up to 500 mm
r6 is an ISO tolerance class for shafts (external features) under ISO 286. At Ø25 mm it means +41 / +28 µm: the size may lie between 25.028 and 25.041 mm. Below are the deviations for every nominal size up to 500 mm and the fits that use r6.
r6 chart: deviations for all nominal sizes up to 500 mm
Deviations in µm (1 µm = 0.001 mm). A nominal size belongs to the row »over … up to and including …«: exactly 30 mm is in the row ending at 30, 30.1 mm in the next one.
| Nominal size over – to (mm) | Upper deviation | Lower deviation | Tolerance |
|---|---|---|---|
| 0 – 3 | +16 | +10 | 6 |
| 3 – 6 | +23 | +15 | 8 |
| 6 – 10 | +28 | +19 | 9 |
| 10 – 18 | +34 | +23 | 11 |
| 18 – 30 | +41 | +28 | 13 |
| 30 – 50 | +50 | +34 | 16 |
| 50 – 65 | +60 | +41 | 19 |
| 65 – 80 | +62 | +43 | 19 |
| 80 – 100 | +73 | +51 | 22 |
| 100 – 120 | +76 | +54 | 22 |
| 120 – 140 | +88 | +63 | 25 |
| 140 – 160 | +90 | +65 | 25 |
| 160 – 180 | +93 | +68 | 25 |
| 180 – 200 | +106 | +77 | 29 |
| 200 – 225 | +109 | +80 | 29 |
| 225 – 250 | +113 | +84 | 29 |
| 250 – 280 | +126 | +94 | 32 |
| 280 – 315 | +130 | +98 | 32 |
| 315 – 355 | +144 | +108 | 36 |
| 355 – 400 | +150 | +114 | 36 |
| 400 – 450 | +166 | +126 | 40 |
| 450 – 500 | +172 | +132 | 40 |
r6 for your nominal size
How r6 is built
An ISO tolerance class is a letter and a number. Capital letters stand for holes, small letters for shafts. The letter r sets the position of the tolerance zone; at Ø25 mm it lies entirely above the nominal size: the shaft is always larger than nominal. The number 6 is the standard tolerance grade IT6: it sets how wide the zone is – 13 µm at Ø25 mm.
The tolerance grows with the nominal size: 6 µm in the smallest row (0 – 3 mm), 40 µm in the largest (450 – 500 mm). On a drawing the class follows the dimension, as in »Ø25 r6«; the inspection plan turns that into the limits 25.028 and 25.041 mm.
Fits with r6 at Ø25 mm
Hole-basis system: the hole is H, the shaft r6. Clearance in µm; a minus means interference. Sorted from the largest minimum clearance to the largest interference.
Frequently asked questions about r6
What does r6 mean?
r6 is an ISO tolerance class for shafts (external features): the letter r sets the position of the tolerance zone, the number 6 the standard tolerance grade IT6. At Ø25 mm that gives +41 / +28 µm, i.e. 25.028 to 25.041 mm.
What are the r6 limits at Ø10 and Ø50 mm?
Ø10 r6: +28 / +19 µm (10.019 to 10.028 mm). Ø50 r6: +50 / +34 µm (50.034 to 50.050 mm).
Is r6 a clearance fit?
A tolerance class on its own is not a fit – only together with its mating part. H7/r6 at Ø25 mm is a interference fit (maximum clearance −7 µm, minimum clearance −41 µm; a minus means interference).
More tolerance classes
Shafts in grade 6: h6 · g6 · f6 · js6 · k6 · m6 · n6 · p6 · s6
All classes at a glance: ISO 286 tolerance charts. The same chart in German: r6 Toleranz.