JS7 tolerance (hole): ISO 286 chart up to 500 mm

JS7 is an ISO tolerance class for holes (internal features) under ISO 286. At Ø25 mm it means +10.5 / −10.5 µm: the size may lie between 24.9895 and 25.0105 mm. Below are the deviations for every nominal size up to 500 mm and the fits that use JS7.

Updated 2026-10-30 · Basis: ISO 286-1:2010 and ISO 286-2:2010 · irot Erstmuster

JS7 chart: deviations for all nominal sizes up to 500 mm

Deviations in µm (1 µm = 0.001 mm). A nominal size belongs to the row »over … up to and including …«: exactly 30 mm is in the row ending at 30, 30.1 mm in the next one.

Nominal size over – to (mm)Upper deviationLower deviationTolerance
0 – 3+5−510
3 – 6+6−612
6 – 10+7.5−7.515
10 – 18+9−918
18 – 30+10.5−10.521
30 – 50+12.5−12.525
50 – 80+15−1530
80 – 120+17.5−17.535
120 – 180+20−2040
180 – 250+23−2346
250 – 315+26−2652
315 – 400+28.5−28.557
400 – 500+31.5−31.563

JS7 for your nominal size

mm

How JS7 is built

An ISO tolerance class is a letter and a number. Capital letters stand for holes, small letters for shafts. The letter JS sets the position of the tolerance zone; at Ø25 mm it lies symmetrically around the nominal size. The number 7 is the standard tolerance grade IT7: it sets how wide the zone is – 21 µm at Ø25 mm.

The tolerance grows with the nominal size: 10 µm in the smallest row (0 – 3 mm), 63 µm in the largest (400 – 500 mm). On a drawing the class follows the dimension, as in »Ø25 JS7«; the inspection plan turns that into the limits 24.9895 and 25.0105 mm.

Fits with JS7 at Ø25 mm

Shaft-basis system: the shaft is h, the hole JS7. Clearance in µm; a minus means interference. Sorted from the largest minimum clearance to the largest interference.

FitTypeMax. clearanceMin. clearance
JS7/h6transition fit23.5−10.5
JS7/h7transition fit31.5−10.5

Frequently asked questions about JS7

What does JS7 mean?

JS7 is an ISO tolerance class for holes (internal features): the letter JS sets the position of the tolerance zone, the number 7 the standard tolerance grade IT7. At Ø25 mm that gives +10.5 / −10.5 µm, i.e. 24.9895 to 25.0105 mm.

What are the JS7 limits at Ø10 and Ø50 mm?

Ø10 JS7: +7.5 / −7.5 µm (9.9925 to 10.0075 mm). Ø50 JS7: +12.5 / −12.5 µm (49.9875 to 50.0125 mm).

Is JS7 a clearance fit?

A tolerance class on its own is not a fit – only together with its mating part. JS7/h6 at Ø25 mm is a transition fit (maximum clearance 23.5 µm, minimum clearance −10.5 µm; a minus means interference).